{"id":2949,"date":"2019-05-20T11:40:23","date_gmt":"2019-05-20T08:40:23","guid":{"rendered":"https:\/\/www.senys.ro\/?p=2949"},"modified":"2020-11-10T12:05:57","modified_gmt":"2020-11-10T12:05:57","slug":"implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca","status":"publish","type":"post","link":"https:\/\/senys.ro\/en\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/","title":{"rendered":"Implementation of fire detection and alarm installations and safety lighting installations for the dormitories of the \"Babe\u0219 Bolyai\" University of Cluj-Napoca"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\">\r\n<h2 class=\"wp-block-heading\"><strong>Context<\/strong><\/h2>\r\n\r\n\r\n\r\n<p>Una dintre cele mai prestigioase universit\u0103\u021bi de stat din Rom\u00e2nia este <strong>Universitatea Babe\u0219-Bolyai (UBB) din Cluj-Napoca<\/strong>. Cu un num\u0103r de peste 41.000 de studen\u021bi \u00eenscri\u0219i la nivel de licen\u021b\u0103, masterat \u0219i doctorat la cele 21 de facult\u0103\u021bi, Universitatea Babe\u0219-Bolyai trebuie s\u0103 asigure spa\u021bii de cazare pentru studen\u021bii care nu locuiesc \u00een Cluj-Napoca.<\/p>\r\n\r\n\r\n\r\n<p>Drept urmare, UBB de\u021bine 17 c\u0103mine studen\u021be\u0219ti pentru cazarea acestora. Dintre acestea, 13 c\u0103mine se afl\u0103 \u00een Complexul Studen\u021besc \u201eHa\u0219deu\u201d, unde sunt caza\u0163i peste 3.000 de studen\u0163i de la facult\u0103\u0163ile Universit\u0103\u0163ii, dar \u015fi doctoranzi \u015fi cadre didactice.<\/p>\r\n\r\n\r\n\r\n<p>Unele dintre cele mai mari unit\u0103\u021bi de cazare din campusul Ha\u0219deu sunt c\u0103minele 14 \u0219i 16. Pentru sporirea securit\u0103\u021bii persoanelor din incinta c\u0103minelor, <strong>UBB trebuie s\u0103 asigure instalarea de sisteme de securitate la incendiu \u0219i echipamente pentru iluminatul de siguran\u021b\u0103<\/strong>.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><strong>Cerin\u021be<\/strong> &#8211; <strong>instala\u021bii de detec\u021bie<\/strong><\/h2>\r\n\r\n\r\n\r\n<div class=\"wp-block-image\">\r\n<figure class=\"alignright\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"222\" class=\"wp-image-3293\" src=\"https:\/\/www.senys.ro\/wp-content\/uploads\/2019\/10\/instala\u021bii_de_detec\u021bie_camin16_babes_bolyai-300x222.jpg\" alt=\"instala\u021bii de detec\u021bie\" srcset=\"https:\/\/senys.ro\/wp-content\/uploads\/2019\/10\/instala\u021bii_de_detec\u021bie_camin16_babes_bolyai-300x222.jpg 300w, https:\/\/senys.ro\/wp-content\/uploads\/2019\/10\/instala\u021bii_de_detec\u021bie_camin16_babes_bolyai-768x568.jpg 768w, https:\/\/senys.ro\/wp-content\/uploads\/2019\/10\/instala\u021bii_de_detec\u021bie_camin16_babes_bolyai-630x466.jpg 630w, https:\/\/senys.ro\/wp-content\/uploads\/2019\/10\/instala\u021bii_de_detec\u021bie_camin16_babes_bolyai-420x310.jpg 420w, https:\/\/senys.ro\/wp-content\/uploads\/2019\/10\/instala\u021bii_de_detec\u021bie_camin16_babes_bolyai-840x621.jpg 840w, https:\/\/senys.ro\/wp-content\/uploads\/2019\/10\/instala\u021bii_de_detec\u021bie_camin16_babes_bolyai-315x233.jpg 315w, https:\/\/senys.ro\/wp-content\/uploads\/2019\/10\/instala\u021bii_de_detec\u021bie_camin16_babes_bolyai.jpg 1000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n\r\n<p>Pentru a realiza acest lucru, departamentul de Repara\u021bii \u0219i \u00centre\u021binere din cadrul UBB a \u00eentocmit un caiet de sarcini pentru <strong>implementarea \u00een c\u0103minele 14 \u0219i 16 a unor instala\u021bii de detec\u021bie, semnalizare \u0219i <a href=\"https:\/\/senys.ro\/en\/blog\/sisteme-inovative-stingere-foc-minimalizare-intreruperi-activitate-business\/\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"alarmare \u00een caz de incendiu (se deschide \u00eentr-o fil\u0103 nou\u0103)\">alarmare \u00een caz de incendiu<\/a><\/strong> \u00een conformitate cu cerin\u021bele ISU, normativele \u0219i standardele de referin\u021b\u0103 \u00een vigoare.<\/p>\r\n\r\n\r\n\r\n<p>De asemenea, tot pentru cele dou\u0103 c\u0103mine din campusul Ha\u0219deu a fost elaborat un caiet de sarcini pentru <strong>realizarea instala\u021biilor electrice pentru <a href=\"https:\/\/senys.ro\/en\/blog\/iluminat-led-vs-iluminat-fluorescent-studiu-comparativ\/\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"iluminatul de siguran\u021b\u0103 (se deschide \u00eentr-o fil\u0103 nou\u0103)\">iluminatul de siguran\u021b\u0103<\/a><\/strong> care s\u0103 respecte reglement\u0103rile specifice.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><strong>Descriere proiect Execu\u021bie instala\u021bii de detec\u021bie, semnalizare \u0219i alarmare \u00een caz de incendiu la c\u0103minele 14 \u0219i 16 din campusul Ha\u0219deu al UBB<\/strong><\/h2>\r\n\r\n\r\n\r\n<p>Cele dou\u0103 c\u0103mine pentru cazarea studen\u021bilor de la Universitatea \u201eBabe\u0219-Bolyai\u201d din Cluj-Napoca dispun de camere pe mai multe etaje, spa\u021bii tehnice, birouri, buc\u0103t\u0103rii, magazii \u0219i holuri de acces.<\/p>\r\n\r\n\r\n\r\n<p><strong>Sistemele pentru siguran\u021ba cl\u0103dirilor \u0219i persoanelor <\/strong>care trebuie s\u0103 existe \u00een astfel de unit\u0103\u021bi sunt compuse din instala\u021bii de detec\u021bie \u0219i alarmare la incendiu. La confirmarea unei situa\u021bii reale de incendiu, se vor declan\u0219a automat sirenele de semnalizare.<\/p>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Detectoare de fum \u0219i temperatur\u0103<\/h4>\r\n\r\n\r\n\r\n<p>\u00cen concordan\u021b\u0103 cu arhitectura \u0219i designul fiec\u0103rei construc\u021bii, echipa Quartz Matrix a implementat instala\u021bii de detec\u021bie pe fiecare dintre ariile de incendiu definite \u00een proiect. Special pentru destina\u021bia spa\u021biilor de protejat, s-au montat detectoare de fum \u0219i temperatur\u0103.<\/p>\r\n\r\n\r\n\r\n<p>Acestea au principii adecvate de <strong>detec\u021bie a \u00eenceputului de incendiu<\/strong>. Este asigurat\u0103 astfel supravegherea automat\u0103 a apari\u021biei unui incendiu, respectiv apari\u021bia fumului \u00een \u00eenc\u0103peri nesupravegheate.<\/p>\r\n\r\n\r\n\r\n<p>De asemenea, au fost instalate butoane manuale pentru semnalizarea incendiului pe toate c\u0103ile de acces\/evacuare. Acestea respect\u0103 prevederile interne \u0219i interna\u021bionale \u00een vigoare.<\/p>\r\n\r\n\r\n\r\n<p>Sunt amplasate \u00een a\u0219a fel \u00eenc\u00e2t s\u0103 permit\u0103 o ac\u021bionare rapid\u0103 \u00een caz de sesizare a unui incendiu \u00eenainte de a fi detectat de detectoarele adresabile.<\/p>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Sisteme de tip digital adresabil<\/h4>\r\n\r\n\r\n\r\n<p>Sistemele instalate de echipa de implementare Quartz Matrix sunt de tip digital adresabil, detectorii de fum \u0219i temperatur\u0103 fiind conecta\u021bi la central\u0103 prin intermediul re\u021belei de cabluri.<\/p>\r\n\r\n\r\n\r\n<p>Butoanele de declan\u0219are manual\u0103 \u0219i sirenele de interior sunt cablate \u00een bucla centralei. Au fost montate sirene de exterior pentru semnalizarea incendiului, precum \u0219i sirene de interior amplasate \u00een locuri de unde pot fi auzite din orice punct al c\u0103minelor.\u00a0<\/p>\r\n\r\n\r\n\r\n<p>Alarmarea \u00een cazul detect\u0103rii unui \u00eenceput de incendiu se face:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>optic la nivelul detectoarelor<\/li>\r\n<li>sonor la nivelul sirenelor adresabile de interior<\/li>\r\n<li>respectiv optic<\/li>\r\n<li>sonor la nivelul sirenelor de exterior<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><strong>Normative \u0219i standarde respectate \u00een cadrul proiectului<\/strong><\/h3>\r\n\r\n\r\n\r\n<p>\u00cen cadrul execu\u021biei proiectului, au fost respectate mai multe acte normative, printre care:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Normativ privind securitatea la incendiu a construc\u021biilor. Partea a III-a \u2013 Instala\u021bii de detec\u021bie, semnalizare \u0219i avertizare incendiu, indicativ P118\/3 &#8211; 2015<\/strong><\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Amplasarea detectoarelor de fum<\/strong> asigur\u0103 distan\u021ba minim\u0103 de siguran\u021b\u0103 la foc fa\u021b\u0103 de corpuri de iluminat \u0219i materiale combustibile.<\/p>\r\n\r\n\r\n\r\n<p><strong>Cablurile de cupru<\/strong> sunt rezistente la foc pentru a \u00eent\u00e2rzia propagarea fl\u0103c\u0103rilor. Tabloul electric aferent centralei de semnalizare incendii este alimentat pe traseu \u0219i ferit de pericolul de incendiu.<\/p>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Normativ<\/h4>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Normativ pentru proiectarea, execu\u021bia \u0219i exploatarea instala\u021biilor electrice aferente cl\u0103dirilor<\/strong>,\u00a0 indicativ I7-2011<\/li>\r\n<li><em>Legea nr. 307\/2006<\/em> privind ap\u0103rarea \u00eempotriva incendiilor<\/li>\r\n<li><em>Legea nr. 10\/1995<\/em> privind calitatea \u00een construc\u021bii, cu modificarile si completarile ulterioare<\/li>\r\n<li><em>ORDIN \u00a0nr. 163\/2007<\/em> pentru aprobarea Normelor generale de ap\u0103rare \u00eempotriva incendiilor<\/li>\r\n<li><em>ORDIN nr. 87\/ 2010 <\/em>pentru aprobarea Metodologiei de autorizare a persoanelor care efectueaz\u0103 lucr\u0103ri \u00een domeniul ap\u0103r\u0103rii \u00eempotriva incendiilor<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Echipamente instalate<\/h4>\r\n\r\n\r\n\r\n<p>\u00cen <strong>c\u0103minul 14<\/strong>, o cl\u0103dire cu subsol, parter \u0219i 6 etaje \u0219i o suprafa\u021b\u0103 desf\u0103\u0219urat\u0103 de 8195.5 mp, a fost instalat\u0103 o <strong>central\u0103 de detec\u021bie \u0219i semnalizare incendiu digital\u0103 adresabil\u0103 cu 14 bucle POLON 6000 \u0219i peste 900 de elemente<\/strong>: detectoare digitale adresabile de fum sau temperatur\u0103 wireless, butoane adresabile de incendiu, sirene adresabile de interior \u0219i sirene conven\u021bionale de exterior.<\/p>\r\n\r\n\r\n\r\n<p><strong>Desfumarea<\/strong> celor dou\u0103 case de sc\u0103ri \u00eenchise, care deservesc nivelurile superioare \u0219i au iluminat natural prin ferestre cu ochiuri mobile, se realizeaz\u0103 prin dispozitive automate cu comand\u0103 manual\u0103.<\/p>\r\n\r\n\r\n\r\n<p>Comanda manual\u0103 a centralei de trape de fum se face prin intermediul unui buton manual amplasat la parterul sc\u0103rilor \u0219i automat de la instala\u021bia de detec\u021bie \u0219i semnalizare incendiu prin intermediul modulelor adresabile.<\/p>\r\n\r\n\r\n\r\n<p>La partea superioar\u0103, casele de sc\u0103ri au dispozitive de evacuare a fumului (trape) cu aria liber\u0103 determinat\u0103 conform normativului P118\/99, art. 2.5.30, de cel pu\u0163in 1 mp, av\u00e2nd asigurate posibilit\u0103\u0163i de deschidere prin comand\u0103 de la nivelul acceselui \u00een cele dou\u0103 case de sc\u0103ri.<\/p>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\"><strong>Central\u0103 de detec\u021bie \u0219i semnalizare incendiu digital\u0103<\/strong><\/h4>\r\n\r\n\r\n\r\n<p>\u00cen <strong>c\u0103minul 16<\/strong>, o cl\u0103dire cu subsol, parter \u0219i 10 etaje \u0219i o suprafa\u021b\u0103 desf\u0103\u0219urat\u0103 de 8896.8 mp, a fost instalat\u0103 o <strong>central\u0103 de detec\u021bie \u0219i semnalizare incendiu digital\u0103 adresabil\u0103 cu 14 bucle POLON 6000 \u0219i peste 700 de elemente<\/strong>:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>detectoare digitale adresabile de fum sau temperatur\u0103 wireless<\/li>\r\n<li>butoane adresabile de incendiu<\/li>\r\n<li>sirene adresabile de interior<\/li>\r\n<li>sirene conven\u021bionale de exterior<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><strong>Descriere proiect Execu\u021bie instala\u021bii de iluminat de siguran\u021b\u0103 la c\u0103minele 14 \u0219i 16 din campusul Ha\u0219deu al UBB<\/strong><\/h2>\r\n\r\n\r\n\r\n<p>Instala\u021biile electrice pentru iluminatul de siguran\u021b\u0103 au fost montate de echipa Quartz Matrix \u00een concordan\u021b\u0103 cu prevederile Normativului I7-2011, cap. 7.23. Aparatele folosite pentru iluminatul de siguran\u021b\u0103 sunt echipate cu balast electronic care poate fi alimentat din sursa principal\u0103 de alimentare a iluminatului normal (re\u021beaua furnizorului), precum \u0219i din sursa de alimentare de securitate (kituri de baterii).<\/p>\r\n\r\n\r\n\r\n<p>Sursa de alimentare de securitate (de rezerv\u0103) a fost aleas\u0103 astfel \u00eenc\u00e2t s\u0103 intre \u00een func\u021biune \u00een timpul agreat \u0219i s\u0103 men\u021bin\u0103 alimentarea un timp minim de 1 or\u0103. Excep\u021bie face iluminatul pentru continuarea lucrului care trebuie asigurat pe o durat\u0103 de timp stabilit\u0103 \u00een func\u021bie de tipul activit\u0103\u021bii.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><strong>Tipuri de iluminat de siguran\u021b\u0103 instalate \u00een c\u0103minele 14 \u0219i 16 ale UBB<\/strong><\/h3>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\"><strong>Iluminatul de siguran\u021b\u0103 de securitate pentru evacuare<\/strong><\/h4>\r\n\r\n\r\n\r\n<p>Are scopul de a asigura identificarea \u0219i folosirea, \u00een condi\u021bii de securitate, a c\u0103ilor de evacuare. Corpurile de iluminat pentru evacuare au fost amplasate astfel \u00eenc\u00e2t s\u0103 asigure un nivel de iluminare adecvat.<\/p>\r\n\r\n\r\n\r\n<p>Acesta este conform reglement\u0103rilor specifice referitoare la execu\u021bia sistemelor de iluminat artificial din cl\u0103diri.<\/p>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Aplasare corpuri de iluminat de siguran\u021b\u0103<\/h4>\r\n\r\n\r\n\r\n<p>Corpurile de iluminat sunt situate l\u00e2ng\u0103 fiecare u\u0219\u0103 de ie\u0219ire \u0219i \u00een locurile unde este necesar s\u0103 fie semnalizat un pericol poten\u021bial sau amplasamentul unui echipament de siguran\u021b\u0103, dup\u0103 cum urmeaz\u0103:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>La fiecare u\u0219\u0103 de ie\u0219ire destinat\u0103 folosirii \u00een caz de urgen\u021b\u0103<\/li>\r\n<li>\u00cen exteriorul \u0219i l\u00e2ng\u0103 fiecare ie\u0219ire din cl\u0103dire<\/li>\r\n<li>La panourile\/indicatoarele de semnalizare de securitate<\/li>\r\n<li>La fiecare schimbare de direc\u021bie<\/li>\r\n<li>L\u00e2ng\u0103 fiecare echipament de interven\u021bie \u00eempotriva incendiului (sting\u0103toare) \u0219i fiecare punct de alarm\u0103 (declan\u0219atoare manuale de alarm\u0103 \u00een caz de incendiu), panouri repetoare de semnalizare \u0219i\/sau comand\u0103 \u00een caz de incendiu<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p>Punerea \u00een func\u021biune a sistemului de iluminat de securitate pentru evacuare se face \u00een maximum 5 secunde de la \u00eentreruperea iluminatului normal.<\/p>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\"><strong>Iluminatul de siguran\u021b\u0103 de securitate pentru marcarea hidran\u021bilor interiori de incendiu<\/strong><\/h4>\r\n\r\n\r\n\r\n<p>Este prev\u0103zut s\u0103 permit\u0103 identificarea u\u0219oar\u0103 a hidran\u021bilor interiori de incendiu \u00een lipsa iluminatului normal. Punerea \u00een func\u021biune a sistemului de iluminat de securitate pentru marcarea hidran\u021bilor se face \u00een maximum 5 secunde de la \u00eentreruperea iluminatului normal.<\/p>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\"><strong>Iluminatul de siguran\u021b\u0103 pentru continuarea lucrului<\/strong><\/h4>\r\n\r\n\r\n\r\n<p>Este prev\u0103zut \u00een spa\u021biile dotate cu receptoare care trebuie alimentate f\u0103r\u0103 \u00eentrerupere: instala\u021bii cu rol de securitate la foc \u2013 <a href=\"https:\/\/www.qmart.ro\/proiectare-instalatii-detectare-semnalizare-si-alarmare-incendiu?search_query=centrala+semnalizare+incendiu&amp;results=2\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\"central\u0103 semnalizare incendiu (se deschide \u00eentr-o fil\u0103 nou\u0103)\">central\u0103 semnalizare incendiu<\/a>, tablouri de distribu\u021bie sau \u00eenc\u0103peri cu echipamente de comand\u0103 pentru instala\u021bii de securitate antiefrac\u021bie.<\/p>\r\n\r\n\r\n\r\n<p>Func\u021bionarea iluminatului de siguran\u021b\u0103 pentru aceste spa\u021bii asigur\u0103 continuarea lucrului pe timpul necesar pentru luarea unor m\u0103suri care s\u0103 nu pun\u0103 persoanele implicate \u00een pericol.<\/p>\r\n\r\n\r\n\r\n<p>Timpul de punere \u00een func\u021biune a iluminatului de siguran\u021b\u0103 pentru continuarea lucrului este \u00eentre 0,5 \u0219i 5 secunde de la \u00eentreruperea iluminatului normal.<\/p>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\"><strong>Iluminat de siguran\u021b\u0103 de securitate \u00eempotriva panicii<\/strong><\/h4>\r\n\r\n\r\n\r\n<p>Este partea iluminatului de securitate destinat s\u0103 evite panica \u0219i s\u0103 asigure nivelul de iluminare care s\u0103 permit\u0103 persoanelor s\u0103 ajung\u0103 \u00een locul de unde calea de evacuare poate fi identificat\u0103.<\/p>\r\n\r\n\r\n\r\n<p>Aparatele pentru aceste tipuri de iluminat sunt echipate cu LED-uri. Acestea respect\u0103 recomand\u0103rile din SR EN 60598-2-22:2004 \u0219i tipurile de marcaj stabilite prin HG nr. 971\/2006, precum \u0219i SR EN 1838:2003 privind distan\u021bele de identificare, luminan\u021b\u0103 \u0219i iluminarea panourilor de semnalizare de securitate.<\/p>\r\n\r\n\r\n\r\n<p>Cablurile pentru circuitele de iluminat de siguran\u021b\u0103 sunt de tip CYYF pentru \u00eent\u00e2rzierea propag\u0103rii fl\u0103c\u0103rii.<\/p>\r\n\r\n\r\n\r\n<p>La alegerea traseelor de cablu s-a avut \u00een vedere selectarea celor mai scurte trasee \u00eentre echipamentele electrice, evitarea zonelor care pericliteaz\u0103 integritatea sau buna func\u021bionare a cablurilor prin deterior\u0103ri mecanice, vibra\u021bii, supra\u00eenc\u0103lzire sau arcuri electrice provocate de alte cabluri, precum \u0219i asigurarea accesului la cabluri pentru lucr\u0103ri de montaj \u0219i \u00eentre\u021binere.<\/p>\r\n\r\n\r\n\r\n<p>Cablurile sunt protejate \u00een tuburi protective \u0219i plinte dimensionate corespunz\u0103tor.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><strong>Normative \u0219i standarde respectate \u00een cadrul proiectului<\/strong><\/h3>\r\n\r\n\r\n\r\n<p>Aparatele de iluminat s-au montat respect\u00e2ndu-se condi\u021biile din Normativul NP-061-2002 \u0219i SR 12294\/1993. Iat\u0103 \u0219i alte standarde \u0219i normative care au fost respectate \u00een cadrul lucr\u0103rii:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Legea nr. 10\/1995<\/strong> privind calitatea \u00een construc\u021bii, cu modific\u0103rile \u0219i complet\u0103rile ulterioare<\/li>\r\n<li>Normativ pentru proiectarea, execu\u021bia \u0219i exploatarea instala\u021biilor electrice aferente cl\u0103dirilor,\u00a0 <strong>indicativ I7-2011<\/strong><\/li>\r\n<li><em>Ordinul 166\/2010<\/em> pentru aprobarea dispozi\u021biilor generale privind ap\u0103rarea \u00eempotriva incendiilor la construc\u021bii \u0219i instala\u021bii eferente<\/li>\r\n<li><em>C300-94<\/em> \u2013 normativ de prevenire \u0219i stingere a incendiilor pe durata execut\u0103rii lucr\u0103rilor de construc\u021bii \u0219i instala\u021bii aferente acestora<\/li>\r\n<li><em>C56-2002<\/em> \u2013 normativ pentru verificarea calit\u0103\u021bii lucr\u0103rilor de construc\u021bii \u0219i a instala\u021biilor aferente<\/li>\r\n<li><em>SR CEI 60050-195:2006<\/em>, <em>SR CEI 60050-826:2006<\/em>, <em>SR CEI 61200-413:2005<\/em>, <em>SR HD 193 S2:2002<\/em>, <em>SR EN 60529:1995\/A1:2003<\/em>, <em>SR EN 61140:2002\/A1:2007<\/em><\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><strong>Ce spun beneficiarii<\/strong><\/h3>\r\n\r\n\r\n\r\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\r\n<p><em>\u201eInstalarea unor echipamente la standarde ridicate pentru ca studen\u021bii care sunt caza\u021bi \u00een c\u0103minele 14 \u0219i 16 din Complexul Studen\u021besc Ha\u0219deu s\u0103 se simt\u0103 \u00een siguran\u021b\u0103 era un element esen\u021bial pentru universitatea noastr\u0103. <\/em><\/p>\r\n<p><em>Mul\u021bumit\u0103 companiei Quartz Matrix, implementarea instala\u021biilor de securitate la incendiu \u0219i a celor pentru iluminat de siguran\u021b\u0103 s-a realizat \u00een termenii agrea\u021bi \u0219i la calitatea a\u0219teptat\u0103. <\/em><\/p>\r\n<p><em>At\u00e2t managementul de proiect, c\u00e2t \u0219i modul de lucru \u0219i aten\u021bia la detalii ne-au demonstrat c\u0103 aceast\u0103 colaborare cu Quartz Matrix a fost decizia potrivit\u0103 pentru UBB.\u201d<\/em><\/p>\r\n<cite>Andrei Maier, Universitatea Babe\u0219-Bolyai Cluj-Napoca<\/cite><\/blockquote>\r\n<\/div><!-- .vgblk-rw-wrapper -->","protected":false},"excerpt":{"rendered":"<p>Context Una dintre cele mai prestigioase universit\u0103\u021bi de stat din Rom\u00e2nia este Universitatea Babe\u0219-Bolyai (UBB) din Cluj-Napoca. Cu un num\u0103r de peste 41.000 de studen\u021bi \u00eenscri\u0219i la nivel de licen\u021b\u0103, masterat \u0219i doctorat la cele 21 de facult\u0103\u021bi, Universitatea Babe\u0219-Bolyai trebuie s\u0103 asigure spa\u021bii de cazare pentru studen\u021bii care nu locuiesc \u00een Cluj-Napoca. Drept urmare,&#8230;<\/p>","protected":false},"author":11,"featured_media":2986,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[129,96],"tags":[258,259,260,261,262,263],"class_list":["post-2949","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-securitate-la-incendiu","category-studii-de-caz","tag-centrala-incendiu-polon-6000","tag-iluminat-de-siguranta","tag-instalatii-alarmare","tag-instalatii-detectie-incendiu","tag-instalatii-semnalizare-incendiu","tag-studiu-de-caz-universitatea-babes-bolyai"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d<\/title>\n<meta name=\"description\" content=\"UBB a \u00eentocmit un caiet de sarcini pentru implementarea unor instala\u021bii de detec\u021bie, semnalizare \u0219i alarmare \u00een caz de incendiu.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/senys.ro\/en\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d din Cluj-Napoca\" \/>\n<meta property=\"og:description\" content=\"UBB a \u00eentocmit un caiet de sarcini pentru implementarea unor instala\u021bii de detec\u021bie, semnalizare \u0219i alarmare \u00een caz de incendiu.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/senys.ro\/en\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/\" \/>\n<meta property=\"og:site_name\" content=\"SENYS\" \/>\n<meta property=\"article:published_time\" content=\"2019-05-20T08:40:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-11-10T12:05:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/senys.ro\/wp-content\/uploads\/2019\/05\/centrala-incendiu-polon-alfa-6000.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1657\" \/>\n\t<meta property=\"og:image:height\" content=\"761\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Cojocariu Ovidiu\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Cojocariu Ovidiu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/\"},\"author\":{\"name\":\"Cojocariu Ovidiu\",\"@id\":\"https:\\\/\\\/senys.ro\\\/#\\\/schema\\\/person\\\/fdd2fd73f01ab8d621bf3091c17917a6\"},\"headline\":\"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d din Cluj-Napoca\",\"datePublished\":\"2019-05-20T08:40:23+00:00\",\"dateModified\":\"2020-11-10T12:05:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/\"},\"wordCount\":1931,\"publisher\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/senys.ro\\\/wp-content\\\/uploads\\\/2019\\\/05\\\/centrala-incendiu-polon-alfa-6000.jpg\",\"keywords\":[\"centrala incendiu polon 6000\",\"iluminat de siguranta\",\"instalatii alarmare\",\"instalatii detectie incendiu\",\"instalatii semnalizare incendiu\",\"studiu de caz universitatea babes bolyai\"],\"articleSection\":[\"Securitate la incendiu\",\"Studii de caz\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/senys.ro\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/\",\"url\":\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/\",\"name\":\"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/senys.ro\\\/wp-content\\\/uploads\\\/2019\\\/05\\\/centrala-incendiu-polon-alfa-6000.jpg\",\"datePublished\":\"2019-05-20T08:40:23+00:00\",\"dateModified\":\"2020-11-10T12:05:57+00:00\",\"description\":\"UBB a \u00eentocmit un caiet de sarcini pentru implementarea unor instala\u021bii de detec\u021bie, semnalizare \u0219i alarmare \u00een caz de incendiu.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/#primaryimage\",\"url\":\"https:\\\/\\\/senys.ro\\\/wp-content\\\/uploads\\\/2019\\\/05\\\/centrala-incendiu-polon-alfa-6000.jpg\",\"contentUrl\":\"https:\\\/\\\/senys.ro\\\/wp-content\\\/uploads\\\/2019\\\/05\\\/centrala-incendiu-polon-alfa-6000.jpg\",\"width\":1657,\"height\":761,\"caption\":\"centrala-incendiu-polon-alfa-6000\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/senys.ro\\\/blog\\\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/senys.ro\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d din Cluj-Napoca\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/senys.ro\\\/#website\",\"url\":\"https:\\\/\\\/senys.ro\\\/\",\"name\":\"SENYS\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/senys.ro\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/senys.ro\\\/#organization\",\"name\":\"SENYS\",\"url\":\"https:\\\/\\\/senys.ro\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/senys.ro\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/senys.ro\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/white2Senys__landscape_color-Copy.jpg\",\"contentUrl\":\"https:\\\/\\\/senys.ro\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/white2Senys__landscape_color-Copy.jpg\",\"width\":484,\"height\":108,\"caption\":\"SENYS\"},\"image\":{\"@id\":\"https:\\\/\\\/senys.ro\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/senys.ro\\\/#\\\/schema\\\/person\\\/fdd2fd73f01ab8d621bf3091c17917a6\",\"name\":\"Cojocariu Ovidiu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c7df12ec61b9af6bbf34c149f243a7a40881dfbd3c475dee966b85b743ecb269?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c7df12ec61b9af6bbf34c149f243a7a40881dfbd3c475dee966b85b743ecb269?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c7df12ec61b9af6bbf34c149f243a7a40881dfbd3c475dee966b85b743ecb269?s=96&d=mm&r=g\",\"caption\":\"Cojocariu Ovidiu\"},\"url\":\"https:\\\/\\\/senys.ro\\\/en\\\/author\\\/adminqm\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d","description":"UBB a \u00eentocmit un caiet de sarcini pentru implementarea unor instala\u021bii de detec\u021bie, semnalizare \u0219i alarmare \u00een caz de incendiu.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/senys.ro\/en\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/","og_locale":"en_US","og_type":"article","og_title":"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d din Cluj-Napoca","og_description":"UBB a \u00eentocmit un caiet de sarcini pentru implementarea unor instala\u021bii de detec\u021bie, semnalizare \u0219i alarmare \u00een caz de incendiu.","og_url":"https:\/\/senys.ro\/en\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/","og_site_name":"SENYS","article_published_time":"2019-05-20T08:40:23+00:00","article_modified_time":"2020-11-10T12:05:57+00:00","og_image":[{"width":1657,"height":761,"url":"https:\/\/senys.ro\/wp-content\/uploads\/2019\/05\/centrala-incendiu-polon-alfa-6000.jpg","type":"image\/jpeg"}],"author":"Cojocariu Ovidiu","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Cojocariu Ovidiu","Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/#article","isPartOf":{"@id":"https:\/\/senys.ro\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/"},"author":{"name":"Cojocariu Ovidiu","@id":"https:\/\/senys.ro\/#\/schema\/person\/fdd2fd73f01ab8d621bf3091c17917a6"},"headline":"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d din Cluj-Napoca","datePublished":"2019-05-20T08:40:23+00:00","dateModified":"2020-11-10T12:05:57+00:00","mainEntityOfPage":{"@id":"https:\/\/senys.ro\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/"},"wordCount":1931,"publisher":{"@id":"https:\/\/senys.ro\/#organization"},"image":{"@id":"https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/#primaryimage"},"thumbnailUrl":"https:\/\/senys.ro\/wp-content\/uploads\/2019\/05\/centrala-incendiu-polon-alfa-6000.jpg","keywords":["centrala incendiu polon 6000","iluminat de siguranta","instalatii alarmare","instalatii detectie incendiu","instalatii semnalizare incendiu","studiu de caz universitatea babes bolyai"],"articleSection":["Securitate la incendiu","Studii de caz"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/senys.ro\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/","url":"https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/","name":"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d","isPartOf":{"@id":"https:\/\/senys.ro\/#website"},"primaryImageOfPage":{"@id":"https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/#primaryimage"},"image":{"@id":"https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/#primaryimage"},"thumbnailUrl":"https:\/\/senys.ro\/wp-content\/uploads\/2019\/05\/centrala-incendiu-polon-alfa-6000.jpg","datePublished":"2019-05-20T08:40:23+00:00","dateModified":"2020-11-10T12:05:57+00:00","description":"UBB a \u00eentocmit un caiet de sarcini pentru implementarea unor instala\u021bii de detec\u021bie, semnalizare \u0219i alarmare \u00een caz de incendiu.","breadcrumb":{"@id":"https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/#primaryimage","url":"https:\/\/senys.ro\/wp-content\/uploads\/2019\/05\/centrala-incendiu-polon-alfa-6000.jpg","contentUrl":"https:\/\/senys.ro\/wp-content\/uploads\/2019\/05\/centrala-incendiu-polon-alfa-6000.jpg","width":1657,"height":761,"caption":"centrala-incendiu-polon-alfa-6000"},{"@type":"BreadcrumbList","@id":"https:\/\/senys.ro\/blog\/implementare-instalatii-detectie-alarmare-incendiu-iluminat-siguranta-camine-universitate-babes-bolyai-cluj-napoca\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/senys.ro\/"},{"@type":"ListItem","position":2,"name":"Implementare instala\u021bii de detec\u021bie \u0219i alarmare \u00een caz de incendiu \u0219i instala\u021bii iluminat de siguran\u021b\u0103 pentru c\u0103minele Universit\u0103\u021bii \u201eBabe\u0219 Bolyai\u201d din Cluj-Napoca"}]},{"@type":"WebSite","@id":"https:\/\/senys.ro\/#website","url":"https:\/\/senys.ro\/","name":"SENYS","description":"","publisher":{"@id":"https:\/\/senys.ro\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/senys.ro\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/senys.ro\/#organization","name":"SENYS","url":"https:\/\/senys.ro\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/senys.ro\/#\/schema\/logo\/image\/","url":"https:\/\/senys.ro\/wp-content\/uploads\/2020\/08\/white2Senys__landscape_color-Copy.jpg","contentUrl":"https:\/\/senys.ro\/wp-content\/uploads\/2020\/08\/white2Senys__landscape_color-Copy.jpg","width":484,"height":108,"caption":"SENYS"},"image":{"@id":"https:\/\/senys.ro\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/senys.ro\/#\/schema\/person\/fdd2fd73f01ab8d621bf3091c17917a6","name":"Cojocariu Ovidiu","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c7df12ec61b9af6bbf34c149f243a7a40881dfbd3c475dee966b85b743ecb269?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c7df12ec61b9af6bbf34c149f243a7a40881dfbd3c475dee966b85b743ecb269?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c7df12ec61b9af6bbf34c149f243a7a40881dfbd3c475dee966b85b743ecb269?s=96&d=mm&r=g","caption":"Cojocariu Ovidiu"},"url":"https:\/\/senys.ro\/en\/author\/adminqm\/"}]}},"_links":{"self":[{"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/posts\/2949","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/comments?post=2949"}],"version-history":[{"count":0,"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/posts\/2949\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/media\/2986"}],"wp:attachment":[{"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/media?parent=2949"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/categories?post=2949"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/senys.ro\/en\/wp-json\/wp\/v2\/tags?post=2949"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}